Corrosion Under Insulation (CUI) Guidelines

Revised

Nonfiction, Science & Nature, Technology, Metallurgy
Cover of the book Corrosion Under Insulation (CUI) Guidelines by , Elsevier Science
View on Amazon View on AbeBooks View on Kobo View on B.Depository View on eBay View on Walmart
Author: ISBN: 9780081007396
Publisher: Elsevier Science Publication: November 26, 2015
Imprint: Woodhead Publishing Language: English
Author:
ISBN: 9780081007396
Publisher: Elsevier Science
Publication: November 26, 2015
Imprint: Woodhead Publishing
Language: English

Corrosion-under-insulation (CUI) refers to the external corrosion of piping and vessels that occurs underneath externally clad/jacketed insulation as a result of the penetration of water. By its very nature CUI tends to remain undetected until the insulation and cladding/jacketing is removed to allow inspection or when leaks occur. CUI is a common problem shared by the refining, petrochemical, power, industrial, onshore and offshore industries.

In the first edition of this book published in 2008, the EFC Working Parties WP13 and WP15 engaged together to provide guidelines on managing CUI with contributions from a number of European refining, petrochemical and offshore companies. The guidelines are intended for use on all plants and installation that contain insulated vessels, piping and equipment. The guidelines cover a risk-based inspection methodology for CUI, inspection techniques and recommended best practice for mitigating CUI, including design of plant and equipment, coatings and the use of thermal spray techniques, types of insulation, cladding/jacketing materials and protection guards. The guidelines also include case studies.

The original document first published in 2008 was very successful and provided an important resource in the continuing battle to mitigate CUI. Many members of the EFC corrosion community requested an update and this has taken between 18-24 months to do so. Hopefully this revised document will continue to serve the community providing a practical source of information on how to monitor and manage insulated systems.

  • Revised and fully updated technical guidance on managing CUI provided by EFC Working Parties WP13 and WP 15
  • Contributions from a number of European refining, petrochemical and offshore companies
  • Extensive appendices that provide additional practical guidance on the implementation of corrosion-under-insulation best practice, collected practical expertise and case studies
View on Amazon View on AbeBooks View on Kobo View on B.Depository View on eBay View on Walmart

Corrosion-under-insulation (CUI) refers to the external corrosion of piping and vessels that occurs underneath externally clad/jacketed insulation as a result of the penetration of water. By its very nature CUI tends to remain undetected until the insulation and cladding/jacketing is removed to allow inspection or when leaks occur. CUI is a common problem shared by the refining, petrochemical, power, industrial, onshore and offshore industries.

In the first edition of this book published in 2008, the EFC Working Parties WP13 and WP15 engaged together to provide guidelines on managing CUI with contributions from a number of European refining, petrochemical and offshore companies. The guidelines are intended for use on all plants and installation that contain insulated vessels, piping and equipment. The guidelines cover a risk-based inspection methodology for CUI, inspection techniques and recommended best practice for mitigating CUI, including design of plant and equipment, coatings and the use of thermal spray techniques, types of insulation, cladding/jacketing materials and protection guards. The guidelines also include case studies.

The original document first published in 2008 was very successful and provided an important resource in the continuing battle to mitigate CUI. Many members of the EFC corrosion community requested an update and this has taken between 18-24 months to do so. Hopefully this revised document will continue to serve the community providing a practical source of information on how to monitor and manage insulated systems.

More books from Elsevier Science

Cover of the book Advances in Heterocyclic Chemistry by
Cover of the book Basic Ship Theory, Combined Volume by
Cover of the book Case Studies in Food Retailing and Distribution by
Cover of the book Soil Reinforcement for Anchor Plates and Uplift Response by
Cover of the book Pyridines: From Lab to Production by
Cover of the book Advances in Imaging and Electron Physics by
Cover of the book Advances in Clinical Chemistry by
Cover of the book Up and Running with AutoCAD 2013 by
Cover of the book Autophagy: Cancer, Other Pathologies, Inflammation, Immunity, Infection, and Aging by
Cover of the book Computer-Assisted and Web-Based Innovations in Psychology, Special Education, and Health by
Cover of the book Advances in Shape Memory Polymers by
Cover of the book Advances in Independent Component Analysis and Learning Machines by
Cover of the book Stem Cell Tools and Other Experimental Protocols by
Cover of the book The Compliance Response to Misconduct Allegations by
Cover of the book Advances in Computers by
We use our own "cookies" and third party cookies to improve services and to see statistical information. By using this website, you agree to our Privacy Policy