Tracheal intubation using the PENTAX Airway Scope

Nonfiction, Health & Well Being, Medical, Specialties, Anesthesiology
Cover of the book Tracheal intubation using the PENTAX Airway Scope by Koichi Tanigawa, Sinji Kusunoki, Takuma Sadamori, Yukari Takenaka, BookBaby
View on Amazon View on AbeBooks View on Kobo View on B.Depository View on eBay View on Walmart
Author: Koichi Tanigawa, Sinji Kusunoki, Takuma Sadamori, Yukari Takenaka ISBN: 9781618427328
Publisher: BookBaby Publication: November 30, 2011
Imprint: Language: English
Author: Koichi Tanigawa, Sinji Kusunoki, Takuma Sadamori, Yukari Takenaka
ISBN: 9781618427328
Publisher: BookBaby
Publication: November 30, 2011
Imprint:
Language: English
The PENTAX-AWS (AWS) is a rigid indirect video laryngoscope developed in Japan. The AWS consists of 2.4-inch full-color built-in monitor screen, a charge-coupled device (CCD) camera, and a PBLADE, a disposable blade designed by referring to computed tomography images of the pharynx and larynx of Japanese adults. Unlike conventional direct laryngoscopes, the PBLADE is formed in an “L” shape so as to fit the oropharyngeal anatomy, thus enabling the operator to obtain an optimal view for tracheal intubation without requiring alignment of the oral, pharyngeal, and tracheal axes. In addition, no specific neck position such as the sniffing position or powerful force is required during a laryngoscopy procedure with the device. These characteristics enable safe and secure tracheal intubation regardless of operator experience, even in some difficult airway cases, such as cervical spine immobilization and difficult laryngoscopy, as well as others. As a result, a number of clinical studies have indicated the efficacy of the AWS.  On the other hand, initial evaluations of the AWS are not always good among well-experienced operators who have been using a Macintosh laryngoscope, since the procedures of tracheal intubation differ between the two devices. In particular, manipulation of a PBLADE in the same manner as a Macintosh laryngoscope blade may make it difficult for operators to perform tracheal intubation using the AWS.  The AWS is not the ultimate device for tracheal intubation. Limited mouth opening and copious secretion or blood in the oral cavity are disadvantageous. Moreover, there is a possibility of difficulty with inserting the PBLADE in patients with anatomical abnormalities of the pharynx or larynx.  Here, we focus on the basic anatomical knowledge and skills needed for proper use of the AWS. By understanding its features and learning the correct procedures, the operator can make the best use of the merits of this device. Our hope is that our instructions will be helpful for obtaining accurate knowledge and proper use of the AWS, as well as understanding its limitations.
View on Amazon View on AbeBooks View on Kobo View on B.Depository View on eBay View on Walmart
The PENTAX-AWS (AWS) is a rigid indirect video laryngoscope developed in Japan. The AWS consists of 2.4-inch full-color built-in monitor screen, a charge-coupled device (CCD) camera, and a PBLADE, a disposable blade designed by referring to computed tomography images of the pharynx and larynx of Japanese adults. Unlike conventional direct laryngoscopes, the PBLADE is formed in an “L” shape so as to fit the oropharyngeal anatomy, thus enabling the operator to obtain an optimal view for tracheal intubation without requiring alignment of the oral, pharyngeal, and tracheal axes. In addition, no specific neck position such as the sniffing position or powerful force is required during a laryngoscopy procedure with the device. These characteristics enable safe and secure tracheal intubation regardless of operator experience, even in some difficult airway cases, such as cervical spine immobilization and difficult laryngoscopy, as well as others. As a result, a number of clinical studies have indicated the efficacy of the AWS.  On the other hand, initial evaluations of the AWS are not always good among well-experienced operators who have been using a Macintosh laryngoscope, since the procedures of tracheal intubation differ between the two devices. In particular, manipulation of a PBLADE in the same manner as a Macintosh laryngoscope blade may make it difficult for operators to perform tracheal intubation using the AWS.  The AWS is not the ultimate device for tracheal intubation. Limited mouth opening and copious secretion or blood in the oral cavity are disadvantageous. Moreover, there is a possibility of difficulty with inserting the PBLADE in patients with anatomical abnormalities of the pharynx or larynx.  Here, we focus on the basic anatomical knowledge and skills needed for proper use of the AWS. By understanding its features and learning the correct procedures, the operator can make the best use of the merits of this device. Our hope is that our instructions will be helpful for obtaining accurate knowledge and proper use of the AWS, as well as understanding its limitations.

More books from BookBaby

Cover of the book Tears, Spaghetti and Angels by Koichi Tanigawa, Sinji Kusunoki, Takuma Sadamori, Yukari Takenaka
Cover of the book The Adventures of Sterling the £1 Coin by Koichi Tanigawa, Sinji Kusunoki, Takuma Sadamori, Yukari Takenaka
Cover of the book Tamales For Gringos by Koichi Tanigawa, Sinji Kusunoki, Takuma Sadamori, Yukari Takenaka
Cover of the book Angels Please! (Book 5) by Koichi Tanigawa, Sinji Kusunoki, Takuma Sadamori, Yukari Takenaka
Cover of the book Benton Johnson and the Tale of Tu’i Malila, Part 1 by Koichi Tanigawa, Sinji Kusunoki, Takuma Sadamori, Yukari Takenaka
Cover of the book Far From Perfect by Koichi Tanigawa, Sinji Kusunoki, Takuma Sadamori, Yukari Takenaka
Cover of the book From the Inner Ear by Koichi Tanigawa, Sinji Kusunoki, Takuma Sadamori, Yukari Takenaka
Cover of the book The Perfection of Yeshua! by Koichi Tanigawa, Sinji Kusunoki, Takuma Sadamori, Yukari Takenaka
Cover of the book The Nagyvradi Brothers by Koichi Tanigawa, Sinji Kusunoki, Takuma Sadamori, Yukari Takenaka
Cover of the book Hi Grandad, I've Got a New Donut by Koichi Tanigawa, Sinji Kusunoki, Takuma Sadamori, Yukari Takenaka
Cover of the book The Find by Koichi Tanigawa, Sinji Kusunoki, Takuma Sadamori, Yukari Takenaka
Cover of the book Seven Stories of Ying and Yang by Koichi Tanigawa, Sinji Kusunoki, Takuma Sadamori, Yukari Takenaka
Cover of the book How to be a Man Magnet by Koichi Tanigawa, Sinji Kusunoki, Takuma Sadamori, Yukari Takenaka
Cover of the book Rock Candy Mountain by Koichi Tanigawa, Sinji Kusunoki, Takuma Sadamori, Yukari Takenaka
Cover of the book An Extremely Uncivil War by Koichi Tanigawa, Sinji Kusunoki, Takuma Sadamori, Yukari Takenaka
We use our own "cookies" and third party cookies to improve services and to see statistical information. By using this website, you agree to our Privacy Policy