A Polymer Cochlear Electrode Array: Atraumatic Deep Insertion, Tripolar Stimulation, and Long-Term Reliability

Nonfiction, Science & Nature, Technology, Electronics, Circuits, Engineering
Cover of the book A Polymer Cochlear Electrode Array: Atraumatic Deep Insertion, Tripolar Stimulation, and Long-Term Reliability by Tae Mok Gwon, Springer Singapore
View on Amazon View on AbeBooks View on Kobo View on B.Depository View on eBay View on Walmart
Author: Tae Mok Gwon ISBN: 9789811304729
Publisher: Springer Singapore Publication: May 24, 2018
Imprint: Springer Language: English
Author: Tae Mok Gwon
ISBN: 9789811304729
Publisher: Springer Singapore
Publication: May 24, 2018
Imprint: Springer
Language: English

This book describes the design, fabrication and evaluation of a polymer-based neural interface for a cochlear electrode array, reviewed in terms of fabrication process, functionality, and reliability. Polymer-based devices have attracted attention in the neural prosthetic field due to their flexibility and compatibility with micro-fabrication process. A liquid crystal polymer (LCP) is an inert, highly water-resistant polymer suitable for the encapsulation of electronic components and as a substrate material for fabricating neural interfaces. The author has designed, fabricated, and evaluated an LCP-based cochlear electrode array for an improved polymer-based cochlear implant. The thesis deals with 3 key topics: atraumatic deep insertion, tripolar stimulation, and long-term reliability. Atraumatic insertion of the intracochlear electrode and resulting preservation of residual hearing have become essential in state–of-the-art cochlear implantation. A novel tapered design of an LCP-based cochlear electrode array is presented to meet such goals. For high-density and pitch-recognizable cochlear implant, channel interaction should be avoided. Local tripolar stimulation using multi-layered electrode sites are shown to achieve highly focused electrical stimulation. This thesis addresses another vital issue in the polymer-based neural implants: the long-term reliability issue. After suggesting a new method of forming mechanical interlocking to improve polymer-metal adhesion, the author performs accelerating aging tests to verify the method’s efficacy. The aforementioned three topics have been thoroughly examined through various in vitro and in vivo studies. Verification foresees the development of LCP-based cochlear electrode array for an atraumatic deep insertion, advanced stimulation, and long-term clinical implant.

View on Amazon View on AbeBooks View on Kobo View on B.Depository View on eBay View on Walmart

This book describes the design, fabrication and evaluation of a polymer-based neural interface for a cochlear electrode array, reviewed in terms of fabrication process, functionality, and reliability. Polymer-based devices have attracted attention in the neural prosthetic field due to their flexibility and compatibility with micro-fabrication process. A liquid crystal polymer (LCP) is an inert, highly water-resistant polymer suitable for the encapsulation of electronic components and as a substrate material for fabricating neural interfaces. The author has designed, fabricated, and evaluated an LCP-based cochlear electrode array for an improved polymer-based cochlear implant. The thesis deals with 3 key topics: atraumatic deep insertion, tripolar stimulation, and long-term reliability. Atraumatic insertion of the intracochlear electrode and resulting preservation of residual hearing have become essential in state–of-the-art cochlear implantation. A novel tapered design of an LCP-based cochlear electrode array is presented to meet such goals. For high-density and pitch-recognizable cochlear implant, channel interaction should be avoided. Local tripolar stimulation using multi-layered electrode sites are shown to achieve highly focused electrical stimulation. This thesis addresses another vital issue in the polymer-based neural implants: the long-term reliability issue. After suggesting a new method of forming mechanical interlocking to improve polymer-metal adhesion, the author performs accelerating aging tests to verify the method’s efficacy. The aforementioned three topics have been thoroughly examined through various in vitro and in vivo studies. Verification foresees the development of LCP-based cochlear electrode array for an atraumatic deep insertion, advanced stimulation, and long-term clinical implant.

More books from Springer Singapore

Cover of the book Ad Hoc Networks by Tae Mok Gwon
Cover of the book Educating for the 21st Century by Tae Mok Gwon
Cover of the book Internet Infidelity by Tae Mok Gwon
Cover of the book Computational Electromagnetics—Retrospective and Outlook by Tae Mok Gwon
Cover of the book Changing Spatial Elements in Chinese Socio-economic Five-year Plan: from Project Layout to Spatial Planning by Tae Mok Gwon
Cover of the book Changing Practices, Changing Education by Tae Mok Gwon
Cover of the book Wearable Sensors and Robots by Tae Mok Gwon
Cover of the book Assessment of Carbon Footprint in Different Industrial Sectors, Volume 1 by Tae Mok Gwon
Cover of the book Physics and Engineering of Metallic Materials by Tae Mok Gwon
Cover of the book Urban Morphology and Housing Market by Tae Mok Gwon
Cover of the book The Evolution and Preservation of the Old City of Lhasa by Tae Mok Gwon
Cover of the book Contemporary Issues and Development in the Global Halal Industry by Tae Mok Gwon
Cover of the book Oxidative Stress: Diagnostic Methods and Applications in Medical Science by Tae Mok Gwon
Cover of the book Theoretical and Experimental Aerodynamics by Tae Mok Gwon
Cover of the book The China Path to Economic Transition and Development by Tae Mok Gwon
We use our own "cookies" and third party cookies to improve services and to see statistical information. By using this website, you agree to our Privacy Policy