Determining the Accuracy of Urine Volume Calculations made by Stationary 2D B-Mode Ultrasonography

Nonfiction, Health & Well Being, Medical, Specialties, Radiology & Nuclear Medicine
Cover of the book Determining the Accuracy of Urine Volume Calculations made by Stationary 2D B-Mode Ultrasonography by Muhammad Shoyab, GRIN Verlag
View on Amazon View on AbeBooks View on Kobo View on B.Depository View on eBay View on Walmart
Author: Muhammad Shoyab ISBN: 9783656894186
Publisher: GRIN Verlag Publication: February 10, 2015
Imprint: GRIN Verlag Language: English
Author: Muhammad Shoyab
ISBN: 9783656894186
Publisher: GRIN Verlag
Publication: February 10, 2015
Imprint: GRIN Verlag
Language: English

Research Paper (postgraduate) from the year 2014 in the subject Medicine - Radiology, Nuclear Medicine, grade: A, , language: English, abstract: This study was the first of its kind in that it fills the gap in the scientific data created by the absence of any investigation making a direct comparison between 2D-sonograhpic and true urine volumes. While most hospitals in the developed world now prefer to measure urine volumes with portable bladder scanners and 3D ultrasound devices, none of these technology are widely available in Bangladesh and other developing countries. Nonetheless, hundreds to thousands of ultrasound examinations involving the measurement of maximum cystometric capacity (MCC) and postvoid residue (PVR) of urinary bladder are done with 2D stationary ultrasound every day. Despite our clinical experience that these measurements are quite accurate and reliable, it was deemed essential to establish scientific evidence in its favour. This observational study was done in the Dept of Radiology & Imaging at Bangabandhu Sheikh Mujib Medical University (BSMMU), Dhaka, Bangladesh, during the period July - December 2014. 384 adult patients who came to BSMMU for ultrasound examinations were enrolled in this study and their true urine volumes were compared against that calculated using 2D B-mode ultrasound. The findings were analysed using two statistical approaches - correlation coefficient and limits of agreement. Calculation of the correlation coefficient was done so that the findings of this study could be compared with other relevant studies, most of which have used the correlation coefficient to assess the accuracy of the ultrasound equipment (3D or portable). However, Bland & Altman's limits of agreement method is the standard statistical approach to assess agreement between two methods of clinical measurement, as determined by The Statistician, The Lancet and others. Findings of this study show that bladder urine volumes measured by 2D B-mode ultrasound had high correlation (r = 0.96, 95% CI 0.955 - 0.969, P < 0.0001) and agreement (96.35%, LoA : -7.84 ± 53.05 mL) with true urine volumes. Sonographic urine volumes were accurate in both males and females, of all adult age groups and at all volume ranges including <100 mL.

View on Amazon View on AbeBooks View on Kobo View on B.Depository View on eBay View on Walmart

Research Paper (postgraduate) from the year 2014 in the subject Medicine - Radiology, Nuclear Medicine, grade: A, , language: English, abstract: This study was the first of its kind in that it fills the gap in the scientific data created by the absence of any investigation making a direct comparison between 2D-sonograhpic and true urine volumes. While most hospitals in the developed world now prefer to measure urine volumes with portable bladder scanners and 3D ultrasound devices, none of these technology are widely available in Bangladesh and other developing countries. Nonetheless, hundreds to thousands of ultrasound examinations involving the measurement of maximum cystometric capacity (MCC) and postvoid residue (PVR) of urinary bladder are done with 2D stationary ultrasound every day. Despite our clinical experience that these measurements are quite accurate and reliable, it was deemed essential to establish scientific evidence in its favour. This observational study was done in the Dept of Radiology & Imaging at Bangabandhu Sheikh Mujib Medical University (BSMMU), Dhaka, Bangladesh, during the period July - December 2014. 384 adult patients who came to BSMMU for ultrasound examinations were enrolled in this study and their true urine volumes were compared against that calculated using 2D B-mode ultrasound. The findings were analysed using two statistical approaches - correlation coefficient and limits of agreement. Calculation of the correlation coefficient was done so that the findings of this study could be compared with other relevant studies, most of which have used the correlation coefficient to assess the accuracy of the ultrasound equipment (3D or portable). However, Bland & Altman's limits of agreement method is the standard statistical approach to assess agreement between two methods of clinical measurement, as determined by The Statistician, The Lancet and others. Findings of this study show that bladder urine volumes measured by 2D B-mode ultrasound had high correlation (r = 0.96, 95% CI 0.955 - 0.969, P < 0.0001) and agreement (96.35%, LoA : -7.84 ± 53.05 mL) with true urine volumes. Sonographic urine volumes were accurate in both males and females, of all adult age groups and at all volume ranges including <100 mL.

More books from GRIN Verlag

Cover of the book Distributionspolitik in der Versicherungswirtschaft by Muhammad Shoyab
Cover of the book Suchmaschinenoptimierung. Ein Eingriff in die eigene digitale Recherche? by Muhammad Shoyab
Cover of the book Die Ausgangslage für die Entwicklung moderner Sozialarbeit - Industrialisierung und Urbanisierung als Wendepunkt in der sozialen Ordnung by Muhammad Shoyab
Cover of the book Aktuelle Rechtssprechungen aus dem Sozialrecht - Die Rechtsprechung des Bundessozialgerichts zu den Rentenabschlägen bei vorgezogener Altersrente by Muhammad Shoyab
Cover of the book Das Ausfüllen eines Überweisungsträgers (Unterweisung Bürokaufmann / -kauffrau) by Muhammad Shoyab
Cover of the book Darstellung und Authentizität von Gottes-Visionen im Werk von Carlos Castaneda by Muhammad Shoyab
Cover of the book Wie wirkt die Technik des 'Inneren Teams' auf das therapeutische Bündnis? by Muhammad Shoyab
Cover of the book Ist die Welt wirklich flach? by Muhammad Shoyab
Cover of the book Das Jugendstrafrecht in Deutschland und dessen Vollzug by Muhammad Shoyab
Cover of the book Die deutsche Ostpolitik und die KSZE als Bedingung der deutschen Einheit by Muhammad Shoyab
Cover of the book Hexenverfolgung in der Gegenwart - Das Beispiel Südafrika by Muhammad Shoyab
Cover of the book Kinder im Trennungs- und Scheidungsprozess der Eltern. Trauma oder Chance ? by Muhammad Shoyab
Cover of the book Die Bedeutung und der Aufbau eines Arbeitsschutzmanagementsystems im Personaleinsatz by Muhammad Shoyab
Cover of the book Geschichte der Erwachsenenbildung by Muhammad Shoyab
Cover of the book Ordnungsgemäß eine Beratervorstellung durchführen (Unterweisung Versicherungskaufmann / -kauffrau) by Muhammad Shoyab
We use our own "cookies" and third party cookies to improve services and to see statistical information. By using this website, you agree to our Privacy Policy